Hi All
I have a 2016 LD 3/4, and have a continuous air suspension issue, defaulting to normal ride height only being available.
I have recently refurbed the compressor, o rings and beads, and did the overnight test with no leaks apparent. I presently have 3 codes showing -
C1A36-01 exhaust valve - intermittent
C1A27-12 compressor circuit - historic
C1A20-64 pressure increases too slow when filling reservoir - permanent
Should I replace the RLCM, the compressor or both? Or is there another issue I’m missing?
Many thanks in advance.
I have a 2016 LD 3/4, and have a continuous air suspension issue, defaulting to normal ride height only being available.
I have recently refurbed the compressor, o rings and beads, and did the overnight test with no leaks apparent. I presently have 3 codes showing -
C1A36-01 exhaust valve - intermittent
C1A27-12 compressor circuit - historic
C1A20-64 pressure increases too slow when filling reservoir - permanent
Should I replace the RLCM, the compressor or both? Or is there another issue I’m missing?
Many thanks in advance.