imortim1
Member
- Posts
- 48
- Location
- Baltimore, MD
Agreed, the FIP just wasn't designed for it. The only time I've seen it done successfully with the DPA was where a dual tank system had been fitted, one with veg oil or biodiesel, one with regular diesel. Engine was started on regular diesel, switched over to veg oil in transit and then switched back to regular diesel at least 15 mins before reaching destination and engine shut off shut to flush out the veg oil. All rather complex and a bit of a faff to be honest. Too easy to get wrong in a hurry. It was being done as an experiment to see if it WAS possible, which it was as long as you were scrupulous about flushing the pump. But the owner went through a few pumps whilst experimenting (not cheap) and eventually gave up on it due to complexity and risk of screwing things up. Went back to dual tank regular diesel in the end if I remember correctly. I was always hungry when around/driving that vehicle though as it did smell good!