I didnt fit a new relay.. just swapped the engine relay for it. now I have a new relay, came w. compressor. I'll fit it. dont see the point tho.
The 3 levels: so yesterday, I did cycle it thru the 3 levels, and it achieved the 3 levels OK, all lights going out. But at normal level sometimes the compressor was cycling almost at 50%, or sometimes even more.
Overnight.. w. fuse out. it did drop a bit. sorry I dont have exact measurements, stupid.. just forgot, I'll guess 1".
This morning, I put the fuse back in.. and put it into offroad height. no problem, and pretty sure the compressor went off. But then I couldnt lower it to 'normal', I get suspension fault, the indicator picture of the car is red (for the first time), and '30mph max' warning appears.
sounds like a sensor or some unloader valve.. what do you think abt my next steps?
TIA.
coffee break .
hi
first thing , fit the new relay that came with the compressor
it sounds also that it's not getting the correct signal to turn off
there are 3 x connectors hidden behind the front passenger side wheel arch
renowned for loose connections there
think that's the next port of call, to carefully check them ,to ensure there sound and sending the correct signal to the pressure switch fitted on the reservoir valve
we can then go from there
with faults like this , it's easier getting a decent diagnostic machine, like the iid