sierrafery
Well-Known Member
- Posts
- 17,872
- Location
- Arad/Romania
With ignition on connect a ground to C0663-5 and see if the HRW switch's tell tale light comes on then or not, if not check for voltage across C0661 - 1 and 15
concentrate hard to not mix pins or put ground or measure elswhere cos it's important to find the problem
all i say must be carried out in situ withoout unplugging anything ... let the BCU exposed cos there is work to be done
concentrate hard to not mix pins or put ground or measure elswhere cos it's important to find the problem
all i say must be carried out in situ withoout unplugging anything ... let the BCU exposed cos there is work to be done
Last edited: