Search results

This site contains affiliate links for which LandyZone may be compensated if you make a purchase.
  1. N

    3.9 v8 classic refusing to start

    No i didn't . Have one on order now just in case. Along with new spark plugs
  2. N

    3.9 v8 classic refusing to start

    Static timing looks ok. I have rotar arm a few degrees before no.1 plug lead, and compression in no.1 cylinder as it rises to the top of its stroke. I guess next step is rocker cover off to be sure i have the right cycle and exhaust valves are definitely shut
  3. N

    3.9 v8 classic refusing to start

    Ok so i changed the ignition amp today and checked the wiring from amp connector to coil. Theres only 2 wires +ve and -ve both were fine. Now i have fuel getting to the plugs and spark at plug lead ends byt she still won't start ?? Battery is fully charged and turning engine over. Hooked up my...
  4. N

    3.9 v8 classic refusing to start

    Once i get the distributor out , i will open up the loom and check the cables. I do have a niggling feeling it may be a bad connection. However while the distributor is out i'll swap the amp as removing the disi is such a PITA.
  5. N

    3.9 v8 classic refusing to start

    Thanks Rimmer Bros have confirmed the lucas coil is compatible.
  6. N

    3.9 v8 classic refusing to start

    This would be my worst nightmare! Never knowing why and waiting for it to happen again.
  7. N

    3.9 v8 classic refusing to start

    Thanks the coil will be 2nd on the list to swap . I have found a brand new lucas coil that i ordered but did'nt use on a previous v8. Is this interchangeable with the bosch unit ? Coil specs seem non existent these days !
  8. N

    3.9 v8 classic refusing to start

    Thanks i wish could but i have no idea how to check it or where to find the information. Rave has no details that i could find. Any info would be much appreciated
  9. N

    3.9 v8 classic refusing to start

    Thank you for the comprehensive reply. I did all those tests. Fuel pump runs for approx 2-3 seconds when ignition is switched on . No spark from the king lead and no fuel getting to the plugs. Will check the other relays but I have ordered a new amplifier as it seems to be the link between...
  10. N

    3.9 v8 classic refusing to start

    I Do have the factory fit immobiliser. I believe it is only set from the remote for central locking which i never use. Have done some more investigation this afternoon. Fuel pump runs for 2 seconds when ignition is first switched to position 2. I checked the plugs after cranking and all are...
  11. N

    3.9 v8 classic refusing to start

    Thanks. It definitely a spark issue. No spark from plug leads or from coil lead to disi cap.
  12. N

    Hello from a Newbie

    I've been very fortunate !!
  13. N

    3.9 v8 classic refusing to start

    Hi hoping someone can advise me please. 94 range rover classic 3.9v8 auto. Started and moved out of my garage yesterday morning ist time it had been started in a month. Left running for e few mins. It turned over e few times before firing whichvwas unusual but i put fown to stale fuel as it has...
  14. N

    Hello from a Newbie

    Hi just registered as I'm going to start re-commissioning my 1994 range rover classic 3.9v8 in the next few months. I've owned it for over 10 tears, but have'nt had much time to use it for the past few years. It's always garaged and has been started and moved regularly. The only major thing...