Have a restful nightNope not saying anything except, good night folks .
J
Have a restful nightNope not saying anything except, good night folks .
J
Gerra Freelander.I think that after owning a rangie and a 90 I need to get a disco to the complete the ensemble
Well, it all looks very jolly now but sooner or later the collection truck will come and tip him out.Home sweet home: living in a converted dumpster – DW – 01/25/2025
Harrison Marshall of England couldn't find an affordable flat in London, so, necessity being the mother of invention, he made his home in a converted dumpster.www.dw.com
Not a freelander thenI think that after owning a rangie and a 90 I need to get a disco to the complete the ensemble
I think that after owning a rangie and a 90 I need to get a disco to the complete the ensemble
MOL, being a sensible chap, knows his LR journey will be complete without a hairdresser's wagonGerra Freelander.
Seen this? Disco by Hyundai.I think that after owning a rangie and a 90 I need to get a disco to the complete the ensemble
I licked it, but only 'cos there ain't a don't lickSeen this? Disco by Hyundai.View attachment 333888
I is 'ereSposed to be rainywindyblow outside
Keep yer T-shirt on, there's another storm blowing in.Morning all, tropical today...... the suns oot better get my shorts on & my suntan lotion looked oot.
Remember that this has been discussed earlier in the week in AG.First ferry boat on its way to this godforsaken rock since Thursday afternoon. The co-op shelves are empty but I do have 15 loaves and 36 toilet rolls, so all’s good. Wind just starting to rise again too
Without reading the thread any further, have you checked the pump over-run thermostat? Mine goes fairly regularly. when it does our boiler kettles a bit and the pipes bang.Me boiler is norappy. Came home last week to hear it bubbling like a kettle. This indicates the water is boiling inside. Eye checked the pressure. It be ok. Eye checked all me rads. They be air free. It was creating hot water for me taps. Its creating hot water for me rads.
Me boiler were struggling to pass water through the heat exchanger. The pump is wukking. Eye know that because it can fill all me rads. Said water is clear. It were replaced not many years ago when eye fitted me magnetic filter. Looked in the filter. Water be clear. Not black like before. Rust inhibiter int system doing its job. Small amount of metal particles on the magnet. Removed em.
So we now fink the heat echanger is blocked or partually blocked. Or somefink part of the process is causing the problem. Me boiler sits at 55 degrees C normally. Whennits struggling is boils at 48 on the display. Thats the output temp. Inside will be hotter if there be no flow or reduced flow, cauding the boil. Tis good to givvit an exercise so eye put it up to 80. It pre-heats and gets there. Over rid me set temps in me heating app to gerrit to heat the rads. It did. Gorrum well hot. So that proves me boiler wuks. But there could be a bit of blockage or the variable speed pump is playing up.
Cheeky sossiddge. Wish I hadn't posted now!
Wot still stinks is that it STILL hasn't gone to trial as if the judge awarded less damages than H was offered then he'd be stuck with part of the the costs.Fink its hoped it can be dug up again for review. The whole **** show. Its said it cost em over a billion sovs in payouts and peeps wukkin onnit.
He seems to keep his water clean so, unless it is scaled to heck, as you say "the sensor" or as I call it, the over-run Tstat. If newer boilers have them. Ours dates back to the stone age, fitted in about 1984/5 and every tech peeps who sees it says the same thing, "Don't EVER get rid of this, they just don't make them as tough and reliable".I would say its the heat exchanger how old is the boiler? As it sounds like its boiling inside it , but there should be a sensor that prevents this so that would also need to be looked at could be part of the problems also a safety issue , very often if a heating system is dirty and not flushed with cleaning liquid and filled with fresh water with the inhibitor, if the inhabitants are added to a dirty system it can cause solidarity of particles and blockages and thay get baked on in the heat exchanger du to the higher temperatures,just my thinking ?