Chema Disco v8
Member
,
No I cannot open themBut can you manually open all the doors now ?
Yeah nothing happensI understood the unlocking thing, answer exactly to my question if you want help
YesSo all the doors except the driver's are stuck closed no matter what you do boot included?
Ok I will try thatActually it might work from the driver's door too if you are lucky but that's not 100% sure... so remove the driver's door card, unplug the actuator and splice with two wires into the pink/grey and pink/purple wires from pins 6 -7(attached) as to be able to feed those wires from outside, connect back the actuator and give earth and +12V to those wires for a second one way then unlock with remote, if nothing happens revert polarity and unlock again with remote... be aware, the extra wires must not be connected to anything while you unlock with the remote you must feed them for a second then let them in the air for remote command if you see what i mean ... do that and report the result, let the door card off for further tests if needed
Ok, i have a couple of doubts before i proceed. When u mean the extra wires cannot be connected to anything… should i pull all of them out of the actuator or need to cut them all and join after the procedure.Actually it might work from the driver's door too if you are lucky but that's not 100% sure... so remove the driver's door card, unplug the actuator and splice with two wires into the pink/grey and pink/purple wires from pins 6 -7(attached) as to be able to feed those wires from outside, connect back the actuator and give earth and +12V to those wires for a second one way then unlock with remote, if nothing happens revert polarity and unlock again with remote... be aware, the extra wires must not be connected to anything while you unlock with the remote you must feed them for a second then let them in the air for remote command if you see what i mean ... do that and report the result, let the door card off for further tests if needed
I dont understand your doubts, i can't explain better than i already did, i said "splice into" which means use posi-taps or skotchlocks or something into the wires as they are, it's nothing about pulling or cutting anything and you can take +12V from the fusebox and earth from any metalic part there.... if you have doubts after you read again carefully what i wrote and it's not clear means that my english is not good enough or you better not play with electricsOk, i have a couple of doubts before i proceed. When u mean the extra wires cannot be connected to anything… should i pull all of them out of the actuator or need to cut them all and join after the procedure.
What would u use to give the 12v and esrth to the cables?