rover75lover
Active Member
- Posts
- 210
- Location
- newport.wales.uk
ive a p 38 1996 diesel auto.
lately the eas pump has been running a lot,every 10 seconds when stood idling ,doors,tailgte etc all closed. I know as the bushes on the eas are worn and ii can hear it rattling.
Two days ago she sat on her stops ant the 35 mph slow,christmas tree lights etc popped up.
I bought some 6 mm pipe fittings, made individual connections to my compressor and individually pressurised each air bag to 8 bar .left them for ten minutes and no pressure was lost. I installed an accurate pressure clock. also installed a tap to release the pressure. when pressurised I used soapy water and couldn't see any bubbles. also checked pressurised the tank as well it held for the ten minutes.
Stripped the compressor and fitted a new seal and liner .
I used the sunlock suite and unlocked the eas fault.
She lifts no problem and then settles,holds seem to drop slightly then the compressor cuts in.the compressor runs,waits for 10 seconds then off it goes running again.
Over night she doesn't seem to drop at all,same measurement wheel to arch night and morning. in the morning when started she rises slightly and then the compressor cycling starts over again.
im wondering if its the pressure switch? could I fit my gauge into the system and check the cut out cut in pressure?
any guidance,advice appreciated
thanks
lately the eas pump has been running a lot,every 10 seconds when stood idling ,doors,tailgte etc all closed. I know as the bushes on the eas are worn and ii can hear it rattling.
Two days ago she sat on her stops ant the 35 mph slow,christmas tree lights etc popped up.
I bought some 6 mm pipe fittings, made individual connections to my compressor and individually pressurised each air bag to 8 bar .left them for ten minutes and no pressure was lost. I installed an accurate pressure clock. also installed a tap to release the pressure. when pressurised I used soapy water and couldn't see any bubbles. also checked pressurised the tank as well it held for the ten minutes.
Stripped the compressor and fitted a new seal and liner .
I used the sunlock suite and unlocked the eas fault.
She lifts no problem and then settles,holds seem to drop slightly then the compressor cuts in.the compressor runs,waits for 10 seconds then off it goes running again.
Over night she doesn't seem to drop at all,same measurement wheel to arch night and morning. in the morning when started she rises slightly and then the compressor cycling starts over again.
im wondering if its the pressure switch? could I fit my gauge into the system and check the cut out cut in pressure?
any guidance,advice appreciated
thanks