Can someone please give me some pointers for my electrical and plumbing problems on my 94 200tdi defender 90. (Ex FFR if this helps, 24V not included)
Started out of the blue last week, lights were like very dim candles coming home and temp uage looked like it was about to explode.
Charged battery, checked earths, checked alternator is charging and all OK.
When I disconnect the earth lead from the battery and run a meter between the battery terminal and the disconected lead, I have a full 12v reading. No sparks whe the terminal lead is struck accross the battery either.
Engine tempreture is running a little high, and poor to no water flow, new pump and thermostat fitted, radiator clear, no crud and water running clear through all pipes and heater matrix OK. When connected up I have no water pressure at all, and no flow of water through the system as though there is a blockage somewhere, but it runs freely with the hose. I have not had it pressure tested yet, but have no smoke, emulsification etc in the oil, I am not using water either, and no loss of power so do not suspect head gasket at this time
Taking her out for a test drive yesterday, I noticed that the temp guage was sitting at about 3/4, but as soon as I put the heater fan or the lights on, the temp guage shot right over to the red so something is shorting out somewhere.
I have disconected all the fuses one by one and the taken the relays out, diconected the heater matrix and all other conections that I can see easily and still getting the 12v reading across the earth.
Checked Rad for cold spots and all ok, Top hose hot, bottom hose less so but warm, seems more like conduction rather than convection. Inlet and outlet Heater matrix pipes very hot, although no real heat in cab
The above two points may or not be connected but scratching my head now and would appreciate some pointers if anyone else has had this issue.
Thanks
Can someone please give me some pointers for my electrical and plumbing problems on my 94 200tdi defender 90. (Ex FFR if this helps, 24V not included)
Started out of the blue last week, lights were like very dim candles coming home and temp uage looked like it was about to explode.
Charged battery, checked earths, checked alternator is charging and all OK.
When I disconnect the earth lead from the battery and run a meter between the battery terminal and the disconected lead, I have a full 12v reading. No sparks whe the terminal lead is struck accross the battery either.
Engine tempreture is running a little high, and poor to no water flow, new pump and thermostat fitted, radiator clear, no crud and water running clear through all pipes and heater matrix OK. When connected up I have no water pressure at all, and no flow of water through the system as though there is a blockage somewhere, but it runs freely with the hose. I have not had it pressure tested yet, but have no smoke, emulsification etc in the oil, I am not using water either, and no loss of power so do not suspect head gasket at this time
Taking her out for a test drive yesterday, I noticed that the temp guage was sitting at about 3/4, but as soon as I put the heater fan or the lights on, the temp guage shot right over to the red so something is shorting out somewhere.
I have disconected all the fuses one by one and the taken the relays out, diconected the heater matrix and all other conections that I can see easily and still getting the 12v reading across the earth.
Checked Rad for cold spots and all ok, Top hose hot, bottom hose less so but warm, seems more like conduction rather than convection. Inlet and outlet Heater matrix pipes very hot, although no real heat in cab
The above two points may or not be connected but scratching my head now and would appreciate some pointers if anyone else has had this issue.
Thanks