angliaalan
New Member
1995 p38 2.5 heater fans not working fuses seem to be ok what and how is the next thing to check
1995 p38 2.5 heater fans not working fuses seem to be ok what and how is the next thing to check
1995 p38 2.5 heater fans not working fuses seem to be ok what and how is the next thing to check
Look at the wiring diagram in RAVE, do the relays operate? If they do not it could be the HEVAC unit, check with a meter to see if the HEVAC signal is there to operate the relay. You could also try putting a live feed on relay pin 5 to see if the motors operate.still no joy
swapped relays checked fuses plugged in other blower motor nothing happening
tried to find a positive in the plug that plugs into motor but could only find a negative
any other suggestions on what to try
As I said, check the control signal from the HEVAC is there to operate the relay. The problem is most likely the fuse box knackered.i put a live wire on terminal 5 in relay 7 n/s fan works speed adjusts up and down
what do i have to do now? is the control panel needing replaced ?