1. C

    big vibration

    New symptom or info us that the vibration now goes away when engine is hot
  2. C

    big vibration

    Td5
  3. C

    big vibration

    Thanks much. Sorry I didn't specify I have a 2000 disco 2 TRI automatic. james
  4. C

    big vibration

    Dear Gents I am trying to locate source of major vibration. It happens at idle and smooths out around 2000rpm. It happens in N, D, 3,2,1 but in R in smoothes out again. Drives fine in all gears. I noticed what I thought was water pump noise a couple weeks back. Now it's quiet. Could a bad quiet...
  5. C

    SLS voltage diff sensors

    I believe I made mistake. When you said to test pin 1 for continuity I used pin1 on ECU not the connector. When I check the connector pin 1 I get no continuity to ground. Now what?
  6. C

    SLS voltage diff sensors

    No I found it in my 'WorkshoP Manual 1999-2003. I thought that was the same publication as Rave- guess not. Thanks for the picture. More fun to come! Thanks
  7. C

    SLS voltage diff sensors

    Awesome! Where is co391?
  8. C

    SLS voltage diff sensors

    At this point I'm confused. Can I have a recap of your thoughts?
  9. C

    SLS voltage diff sensors

    Ok There is continuity from pin 1 to frame ground. Btwn pin 1 and 2 the ohms off the scale ( I don't know how to read). From pin 1 to 3 it was much less ( like a quarter of the scale) as you can see I'm not electrical savy best I can do is follow instructions - maybe
  10. C

    SLS voltage diff sensors

    Oops wrong! There is 5 V When I connect to supply and earth
  11. C

    SLS voltage diff sensors

    Put multimeter on supply to sensor (at sensor) and there is no voltage
  12. C

    SLS voltage diff sensors

    Put continuity tester on frame and on pin 2 and it says ok. I'm not sure if I should be grounding meter somewhere else?
  13. C

    SLS voltage diff sensors

    Ok I put volt meter to both pins- 1 & 4 of 0654 at ecu -and both read 5 V. Also nano reads 5V when plug is disconnected- goes back to .02 when plugged back in. Does mean wire is bad from ECU to sensor?
  14. C

    SLS voltage diff sensors

    I can't see my last message. Anyway it said in detail that I leveled car many times and stored in ECU but as soon as I close nano or turn on ignition I hear the exhaust valve click open and lowers car
  15. C

    SLS voltage diff sensors

    Well I got it to level half a dozen times in the 'sls calibration' section, then followed instructions to save to ECU, changing different settings in 'settings'. In settings I tried 'ECU calibrated' the yes and no setting, when to 'set target values' section and put in 150. Anyway each time I...
  16. C

    SLS voltage diff sensors

    I swapped sensors early on and nothing changed-the right sensor that I knew was working stopped functioning when put on left side. I'm going to try your latest suggestion now.
  17. C

    SLS voltage diff sensors

    Ok will try. There isn't a right and left sensor is there? I bought these sensors here in CR so it is quite possible one doesn't work.
  18. C

    SLS voltage diff sensors

    Sorry keyboard switched to Spanish-'unable to reach target value' was the nano message
  19. C

    SLS voltage diff sensors

    Ok did it. Swapped plugs at compressor. Put in 150 for target heights. This time the right side raised. No movement on left side. Tried to isolate left side by only putting in target height for that side-it wouldnt accept-'invalid target values'. No apparent relationship between target values...
  20. C

    SLS voltage diff sensors

    I see. Well all that raising and lowering didn't accomplish anything. The left sensor reading does not change with the raising etc. and the nanocom only raise and lower the left side. I could not get it to do anything on the right side where the sensor seems to work. At the moment both sides...