How should I divide the 6 meters of cable up?

  • 2X 3mtrs

    Votes: 1 25.0%
  • 1X 4mtr & 1X 2mtr

    Votes: 3 75.0%

  • Total voters
    4

dieseldog69

Well-Known Member
LZIR Despatch Agent
Right, I'm deliberating again, I used to be indecisive but now I'm not so sure :eek::)

Bought some new 25 square cable to replace my cables on the stick welder, they're silly short as they are and I need more flexibility, got a good deal on 6 meters and think that should be plenty, but..........

How do I divvy the cable up?
 
Well the work lead is usually longer than the ground lead, no need form them to be equal length

Correct.

I have mine even because it's a portable unit and having them both fairly close to the work is easier. I also try to get the earth as close to the weld as practical 'cos when 'parts' of what you're welding might still be rusty, a good connection is necessary. If I had a big enough workshop to have a dedicated workstation it might be different, but I doubt it, 'cos for what I do I'd still have to move around .. ;)
 
Well the work lead is usually longer than the ground lead, no need form them to be equal length

I'm tempted to go with 1X 2mtr for the ground and 1X 4mtr for the stinger, I've migrated up to 25 from the original 16mm/sq as I am trying to mitigate amp drop through the longer cables. Got new earth clamp and stinger as well as some DIN quick release connectors as I want to try and make it easier to store and transport, really need to fit a high velocity fan to extend the duty cycle too but it's adequate for what it is and what I do with it currently, next step is to upgrade to a new inverter unit but that's a whole other ball game and I'd need to do a lot more stick welding than I do currently.
 
For those that are interested, all the parts arrived and as the weather was rubbish and I refuse to go out and get soaked to the skin, I decided to get it all sorted.

Take 1 stick welder.
DSC00282.JPG


DSC00283.JPG


DSC00281.JPG


Dismantle the casing and remove the old cables.

DSC00299.JPG


The new female fittings have a small lug on the insulator them to stop them turning when you fit the cables.

DSC00300.JPG


Fit the females and crimp some terminals on the solid ally cables off the transformer and connect them all up.

DSC00303.JPG


DSC00306.JPG


I cut the cables to give me 1X 2mtr for the earth and 1X 4mtr for the electrode holder and these are the new earth clamp and electrode holder.

DSC00277.JPG


DSC00276.JPG


I fitted a terminal on the earth lead first.

DSC00295.JPG


And snugged it up on the earth clamp stud.

DSC00296.JPG


Then fitted the male connector on the other end, this is the same for both the earth clamp and the electrode holder so won't bore you with two of the same piccies LOL

DSC00288.JPG


Measure the insulation that needs stripped back.

DSC00289.JPG


Fit the copper wrap around that will protect the cable as the allen bolt is tightened down.

DSC00290.JPG


Tighten it all snuggly.

DSC00291.JPG

Slide over the insulating rubber boot and job jobbed.

DSC00293.JPG


Then fit the cable on the new electrode holder.
Measure and cut back the insulation to fit inside the holder.

DSC00284.JPG


Slide in the copper clamping strip.

DSC00285.JPG


Tighten it all down, slide on the cover that doubles as the handle and job jobbed.

DSC00286.JPG


Fit the male spigot on the cable end and voila, all done.

DSC00309.JPG


DSC00307.JPG


Will test it out tomorrow night if the weather stays dry :)
 