Fault Finding
In the self-test mode the switch indicates faults by displaying a flashing code.
The sequence to select test mode is :
1/ Press the heating switch with the ignition off
2/ With the switch depressed turn on the ignition switch to Position II
3/ Release the switch, this activates the self-test mode
4/ After 10 seconds the flashing code is displayed.
The flashing code indicates the following faults
1 Flash = Switch overtemperature
2 Flashes = Short circuit and/or interruption in the sensor
3 Flashes = Short circuit and/or interruption in the heating elements.
With the switch set to test mode, maximum heating is selected and both lamps are lit. If a fault is identified the heating is switched off and, after 10 seconds, the left LED switches off , this LED generates the flashing code. If no fault is detected the LED remains unlit.
To return to the test mode the switch is pressed twice and the sequence starts again.
To cancel the test mode the ignition switch is turned off.