a friends 38 00 dse threw up eas fault, i cleared the faults this eve, how ever the compressor wont run unless i tell it too, anybody got any ideas,, thanks
but would the pressure switch fault show up on the eas unlock, am following that thread at t mo also, i have shutdown the eas unlock correctly , this is the first time i ve had any following issues. i thought that the compressor could not run if the thermal switch had cut out even with the eas unlock, thanks
as always guys thanks, you were spot on thermal switch gone, but i think i lost fight to keep her off the coils, 2 sensors a comp seal and a thermal switch and he s changing, fear of the unknown, but at least i ll get to drive a coil conversion and compare. let it begin ha ha . thanks again