Russward
New Member
Hi all, thought I’d share what’s going on with my D2 to see if there’s anything I’m missing.
In June 22 I was travelling along at approx 60 mph when the transmission oil was suddenly dumped and the car lost drive in all gears. I got the car recovered to a local independent Land Rover specialist garage and was informed the the LH oil cooler pipe had failed. After a few weeks trying to source one without any luck the garage managed to get the pipe repaired at a specialist hydraulic company and refitted. The car worked fine for about a week and then I lost forward drive but still had reverse, I got the car back to the garage who informed me the the gearbox was fried which would have been caused in the initial failure.
After some soul searching (I love my D2) I decided to bite the bullet and they ordered and fitted a replacement reconditioned gearbox from Ashcroft. All was well for around 3 weeks when the oil was dumped again from the oil cooler pipe and the car is back at the garage. Having spent the best part of £2500 I am wondering what would cause the pipe to fail again. I am wondering whether if there was a problem with the cooler itself would that cause enough pressure for the pipe to fail, just trying to establish if there is anything else I should be looking at as clearly I’m getting to the point that I am spending more on the car than it’s worth. Thanks in advance.
In June 22 I was travelling along at approx 60 mph when the transmission oil was suddenly dumped and the car lost drive in all gears. I got the car recovered to a local independent Land Rover specialist garage and was informed the the LH oil cooler pipe had failed. After a few weeks trying to source one without any luck the garage managed to get the pipe repaired at a specialist hydraulic company and refitted. The car worked fine for about a week and then I lost forward drive but still had reverse, I got the car back to the garage who informed me the the gearbox was fried which would have been caused in the initial failure.
After some soul searching (I love my D2) I decided to bite the bullet and they ordered and fitted a replacement reconditioned gearbox from Ashcroft. All was well for around 3 weeks when the oil was dumped again from the oil cooler pipe and the car is back at the garage. Having spent the best part of £2500 I am wondering what would cause the pipe to fail again. I am wondering whether if there was a problem with the cooler itself would that cause enough pressure for the pipe to fail, just trying to establish if there is anything else I should be looking at as clearly I’m getting to the point that I am spending more on the car than it’s worth. Thanks in advance.