rover75lover
Active Member
P 38 1996 auto,diesel 2.5 165,000 miles
Recently replaced my head with a tested head. New BMW gasket and new torque bolts.
after 300 miles shes now started overheating ,so ive changed for brand new, the radiator,viscous fan,water pump for a metal impellered type , thermostat.Flushed the head out .
Problem im getting is that she sits lovely above cold but below the first white segment. Now after about 40 miles the needle gets to half way holds for about 10 miles then suddenly needle swings over red light on . If i lift the bonnet theres water all around the expansion cap and if i try to release it loads of pressure.and i have to add about a litre of water and she will climb back down.
HOWEVER if i travel with the heater on hi but not have the fan blowing she seems to run ok and doesnt get over the middle indication. When I stop let her cool ive lost no water.
Is the heater always online so to speak and the blend motor just directs the air with a flap or is the heater controlled by a water valve which switches the water flow off and on? It seems that if i leave the heater on im getting sufficient water flow from and away from the head so to speak
Alternatively
Is this head cracked cracked and im running on borderline
or is my block cracked?
Many thanks
Recently replaced my head with a tested head. New BMW gasket and new torque bolts.
after 300 miles shes now started overheating ,so ive changed for brand new, the radiator,viscous fan,water pump for a metal impellered type , thermostat.Flushed the head out .
Problem im getting is that she sits lovely above cold but below the first white segment. Now after about 40 miles the needle gets to half way holds for about 10 miles then suddenly needle swings over red light on . If i lift the bonnet theres water all around the expansion cap and if i try to release it loads of pressure.and i have to add about a litre of water and she will climb back down.
HOWEVER if i travel with the heater on hi but not have the fan blowing she seems to run ok and doesnt get over the middle indication. When I stop let her cool ive lost no water.
Is the heater always online so to speak and the blend motor just directs the air with a flap or is the heater controlled by a water valve which switches the water flow off and on? It seems that if i leave the heater on im getting sufficient water flow from and away from the head so to speak
Alternatively
Is this head cracked cracked and im running on borderline
or is my block cracked?
Many thanks