ovalandrover
Well-Known Member
- Posts
- 1,610
I have the modulation reading of 17.6% at idle but when it reaches about 2000 rpm it jumps to 68%. The injector set point is 1.6deg and the actual injector is 10.9 which is not correct as it should be within 1/2 deg
I have set the timing up manually to .95mm at TDC and this is a pump that has just been overhauled.
The car starts up on the button and no smoke. this is after the timing chain has been corrected as from my previous post where the timing was out and also the guide was not fitted properly.
can anyone tell me how the injector set point id determined? and i also assume that the actual is set up manually by the dial gauge .
as its raining at the moment so im not going to get wet but will try adjusting the timing tomorrow to get it within limits.
but would like to know how the injector set point is determined
I have set the timing up manually to .95mm at TDC and this is a pump that has just been overhauled.
The car starts up on the button and no smoke. this is after the timing chain has been corrected as from my previous post where the timing was out and also the guide was not fitted properly.
can anyone tell me how the injector set point id determined? and i also assume that the actual is set up manually by the dial gauge .
as its raining at the moment so im not going to get wet but will try adjusting the timing tomorrow to get it within limits.
but would like to know how the injector set point is determined